Item/Function Potential Failure Mode(s) Potential Effect(s) of Failure  Sev Potential Cause(s)/Mechanism(s) of Failure  Occ Current Design Controls  Det  RPN Recommended Action(s)
Center bolt material, Gasket Debris in shaft Poor gas flow 6 Improper material selection, valve exceeding lifetime 5 Material extensively researched  7 210 Screen the valve, more research on proper gaskets and center bolt
Valve Plates/Spring/Gaskets Corrosion of Parts due to gas type Gas leakage, excessive wear, valve failure 8 Incorrect material choice, excessive temperatures 4 None 6 192 Research all material choices
Center bolt and housing Overall height of valve incorrect, Piston interference scar piston, bend rod, valve damage 9 improper dimensions 2 following design parameters closely, check valve clearance with piston 2 36 Run clearance test prior to installation