Overall Fin Efficiency
Overall fin efficiency for an array of fins:
Define terms: Ab: base area exposed to coolant
Af: surface area of a single fin
At: total area including base area and total finned surface, At=Ab+NAf
N: total number of fins
qb
qf
Previous slide