Test of the accuracy of the scheme:

Value of the scaled critical angle of attack
- Werle & Davis (1972): 1.156 < ac < 1.158
- Cebeci et al (1980) ac =1.155
- We: ac=1.157568 on a 40962 mesh. Maybe ten minutes on guan.
The solution near incipient separation was described by F.T. Smith.
Interaction extends the solution only slightly.