Next: Conclusions
Up: Boundary Layer Suction
Previous: Minimum Suction
Impulsively started flow at a=2. Times shown are t=0.5, 1, 2, 4, 8, 16,
and 32 (nondimensionalized with the nose radius.)
The nondimensional wall shear P is kept above 0.2:
Wall shear:

Suction velocity:

It is seen that for transient problems, much spikier suction
distributions suffice initially.
Suction volume:

It is seen that transient suction volumes can be much smaller.
For scaled angle of attack a=4:
Wall shear:

Suction velocity:

Suction volume:

Next: Conclusions
Up: Boundary Layer Suction
Previous: Minimum Suction
10/16/01 0:37:08
10/16/01 0:38:17